iview-colour-desktop-header
iview-colour-header

PlanOp™ – iView colour

Introducing iView Colour! iView Colour is the latest innovation available on iView Pro, designed to further enhance EVAR procedures by empowering clinicians with the new Distance Colour Map.

It offers clinicians a deeper understanding of endograft apposition to the aortic wall using advanced colour-coded visualisation and 3D simulations.

With iView colour, clinicians can now visually detect weak apposition that may result in an endoleak, facilitating risk assessment and simulation comparison understanding.

Distance colour Map

Distance Colour Map is a heatmap designed for clinicians to visualize the identification of potential risk of endoleak. It instantly highlights the apposition gaps between the graft and the aortic wall complementing the Endoleak risk Index.

iview-colour-introduction

The simulation with the 25mm endograft, displays some red/blue areas at the third stent.

🔴 Red area identify a mal apposition (gap ≥ 2mm). This could represent a potential cause of endoleak.
🔵 Blue area identify a good apposition (Gaps = 0mm)

iView-color-opposition-analysis
eri-endoleak-type-1a-risk-index-meter
eri-endoleak-type-1a-risk-index-meter
iView-colour-panel

Join us for a personalized demo of iView colour at Charing Cross 2025.

Latest News

What is a Distance Colour Map?

What is a Distance Colour Map?

With the raise of new AI capabilities, We at PrediSurge are on a mission to shape the future of cardiovascular care. With Predictive simulations, We are leading the transition from traditional imaging(CT Scans) to Patient-Specific Digital Twins empowering physicians and clinical specialists. And, one such innovation is Distance Colour Map – a break through feature in our AI-Driven digital twin solution portfolio.

read more
Jean-Noel Albertini and Simona Zannetti / Full interview

Jean-Noel Albertini and Simona Zannetti / Full interview

This collaboration brings together Medtronic’s industry-leading Endurant™ stent graft with our AI-powered digital twin technology, empowering clinicians with advanced tools for risk assessment and aiming to enable more precise  EVAR planning. Check out the press...

read more
PrediSurge at PVI

PrediSurge at PVI

We’re proud to be part of the Paris Vascular Insights Course, a gathering of the brightest minds in vascular care. We were focused on how PrediSurge’s digital twin technology is redefining precision in procedures like carotid artery stenting. Our team was there to...

read more

Check out our new EVAR planning tool, iView Pro is now available in Europe with Meditronic’s Endurant.

For upcoming EVAR planning solutions of PrediSurge, check out our Social media.

PlanOp™ – iView colour

Introducing iView Colour! iView Colour is the latest innovation available on iView Pro, designed to further enhance EVAR procedures by empowering clinicians with the new Distance Colour Map.

It offers clinicians a deeper understanding of endograft apposition to the aortic wall using advanced colour-coded visualisation and 3D simulations.

With iView colour, clinicians can now visually detect weak apposition that may result in an endoleak, facilitating risk assessment and simulation comparison understanding.

Distance colour Map

Distance Colour Map is a heatmap designed for clinicians to visualize the identification of potential risk of endoleak. It instantly highlights the apposition gaps between the graft and the aortic wall complementing the Endoleak risk Index.
iview-colour-introduction

The simulation with the 25mm endograft, displays some red/blue areas at the third stent.

🔴 Red area identify a mal apposition (gap ≥ 2mm). This could represent a potential cause of endoleak.

🔵 Blue area identify a good apposition (Gaps = 0mm)

iView-color-opposition-analysis
iView-colour-panel
eri-endoleak-type-1a-risk-index-meter
eri-endoleak-type-1a-risk-index-meter

Join us for a personalized demo of iView colour at Charing Cross 2025.

Latest News

What is a Distance Colour Map?

What is a Distance Colour Map?

With the raise of new AI capabilities, We at PrediSurge are on a mission to shape the future of cardiovascular care. With Predictive simulations, We are leading the transition from traditional imaging(CT Scans) to Patient-Specific Digital Twins empowering physicians and clinical specialists. And, one such innovation is Distance Colour Map – a break through feature in our AI-Driven digital twin solution portfolio.

read more
Jean-Noel Albertini and Simona Zannetti / Full interview

Jean-Noel Albertini and Simona Zannetti / Full interview

This collaboration brings together Medtronic’s industry-leading Endurant™ stent graft with our AI-powered digital twin technology, empowering clinicians with advanced tools for risk assessment and aiming to enable more precise  EVAR planning. Check out the press...

read more
PrediSurge at PVI

PrediSurge at PVI

We’re proud to be part of the Paris Vascular Insights Course, a gathering of the brightest minds in vascular care. We were focused on how PrediSurge’s digital twin technology is redefining precision in procedures like carotid artery stenting. Our team was there to...

read more

Check out our new EVAR planning tool, iView Pro is now available in Europe with Meditronic’s Endurant.

For upcoming EVAR planning solutions of PrediSurge, check out our Social media.